Validation Results for PCMT

Generated Thu Jun 26 06:31:26 UTC 2025, FHIR version 4.0.1 for smart.who.int.pcmt#0.1.0 (canonical = http://smart.who.int/pcmt (history)). See Errors Only & IP

Quality Checks
Publisher Version:IG Publisher Version: v2.0.7
Publication Code:n/a . PackageId = smart.who.int.pcmt, Canonical = http://smart.who.int/pcmt
Realm Check for n/a:
  • n/a
Language Info:This IG has no language information
Publication Request:
package-idsmart.who.int.pcmt
version0.1.0
pathhttp://smart.who.int/pcmt/v0.1.0
Pub-Modemilestone
statusdraft
Release-Labelrelease
Sequence (Group)Releases
desc0.1.0 draft release
firsttrue
categorybase
titleSMART Product Catalog
introductionSMART Product Catalog
ci-buildhttp://worldhealthorganization.github.io/smart-pcmt
RelatedIgs(None Found)
  • This IG has never been published
  • Proposed path for this milestone publication should usually be canonical with either sequence or version appended
Supressed Messages:No Suppressed Issues
Dependency Checks:
PackageVersionFHIRCanonicalWeb BaseComment
.. smart.who.int.pcmt0.1.0R4http://smart.who.int/pcmt
... hl7.terminology.r46.4.0 MR4http://terminology.hl7.orghttp://terminology.hl7.org/6.4.0
.... hl7.fhir.uv.extensions.r45.2.0 MR4http://hl7.org/fhir/extensionshttp://hl7.org/fhir/extensions/5.2.0
... hl7.fhir.uv.extensions.r45.2.0 MR4http://hl7.org/fhir/extensionshttp://hl7.org/fhir/extensions/5.2.0see above
... smart.who.int.base0.1.0 OR4http://smart.who.int/basehttp://smart.who.int/base/0.1.0Latest Release is 0.2.0
.... hl7.terminology5.5.0 OR4http://terminology.hl7.orghttp://terminology.hl7.org/5.5.0Latest Release is 6.4.0
..... hl7.fhir.uv.extensions.r41.0.0 OR4http://hl7.org/fhir/extensionshttp://hl7.org/fhir/extensions/1.0.0Latest Release is 5.2.0
.... hl7.fhir.uv.extensions.r45.1.0 OR4http://hl7.org/fhir/extensionshttp://hl7.org/fhir/extensions/5.1.0Latest Release is 5.2.0
.... hl7.fhir.uv.cql1.0.0 MR4http://hl7.org/fhir/uv/cqlhttp://hl7.org/fhir/uv/cql/STU1
..... hl7.terminology5.5.0 OR4http://terminology.hl7.orghttp://terminology.hl7.org/5.5.0see above. Latest Release is 6.4.0
..... hl7.fhir.uv.extensions.r45.1.0 OR4http://hl7.org/fhir/extensionshttp://hl7.org/fhir/extensions/5.1.0see above. Latest Release is 5.2.0
.... hl7.fhir.uv.crmi1.0.0 MR4http://hl7.org/fhir/uv/crmihttp://hl7.org/fhir/uv/crmi/STU1
..... hl7.terminology5.5.0 OR4http://terminology.hl7.orghttp://terminology.hl7.org/5.5.0see above. Latest Release is 6.4.0
..... hl7.fhir.uv.extensions.r45.1.0 OR4http://hl7.org/fhir/extensionshttp://hl7.org/fhir/extensions/5.1.0see above. Latest Release is 5.2.0
.... hl7.fhir.uv.sdc3.0.0 MR4http://hl7.org/fhir/uv/sdchttp://hl7.org/fhir/uv/sdc/STU3
..... hl7.fhir.r4.examples4.0.1 OR4http://hl7.org/fhirhttp://hl7.org/fhir/R4Latest Release is 5.0.0
.... hl7.terminology.r46.3.0 OR4http://terminology.hl7.orghttp://terminology.hl7.org/6.3.0Latest Release is 6.4.0
..... hl7.fhir.uv.extensions.r45.2.0 MR4http://hl7.org/fhir/extensionshttp://hl7.org/fhir/extensions/5.2.0see above
.... hl7.fhir.uv.extensions.r45.2.0 MR4http://hl7.org/fhir/extensionshttp://hl7.org/fhir/extensions/5.2.0see above
.... ihe.iti.balp1.1.3 MR4https://profiles.ihe.net/ITI/BALPhttps://profiles.ihe.net/ITI/BALP/1.1.3
..... hl7.terminology.r45.3.0 OR4http://terminology.hl7.orghttp://terminology.hl7.org/5.3.0Latest Release is 6.4.0
..... hl7.fhir.uv.extensions.r41.0.0 OR4http://hl7.org/fhir/extensionshttp://hl7.org/fhir/extensions/1.0.0see above. Latest Release is 5.2.0
Templates: who.template.root#current -> fhir.base.template#current. Tools: 0.5.0
Related IGs:n/a
Dependent IGs:no references
Global Profiles:(none declared)
Terminology Server(s):https://tx.fhir.org/r4 (details)
HTA Analysis:Non-HL7 Igs are exempt from terminology dependency analysis
R5 Dependencies:(none)
Draft Dependencies:
Modifier Extensions:(none)
Previous Version Comparison: Unable to compare with previous version: Unable to find version history at http://smart.who.int/pcmt (Problem #1 with package-list.json at http://smart.who.int/pcmt: Not Found)
IPA Comparison: n/a
IPS Comparison: n/a
Validation Flags: On: autoLoad; Off: hintAboutNonMustSupport, anyExtensionsAllowed, checkAggregation, showReferenceMessages, noExperimentalContent, displayWarnings
Summary: errors = 0, warn = 22, info = 6, broken links = 6, pinned = n/a.
FilenameErrorsWarningsHints
Build Errors600
/workspace/temp/ig-builds/smart.who.int.pcmt#0.1.0/fsh-generated/resources/CodeSystem-AttributeType021
/workspace/temp/ig-builds/smart.who.int.pcmt#0.1.0/fsh-generated/resources/CodeSystem-ProductRelationship021
/workspace/temp/ig-builds/smart.who.int.pcmt#0.1.0/fsh-generated/resources/CodeSystem-RegulatationType021
/workspace/temp/ig-builds/smart.who.int.pcmt#0.1.0/fsh-generated/resources/CodeSystem-Status021
/workspace/temp/ig-builds/smart.who.int.pcmt#0.1.0/fsh-generated/resources/CodeSystem-pcmt-glossary-cs021
/workspace/temp/ig-builds/smart.who.int.pcmt#0.1.0/fsh-generated/resources/ImplementationGuide-smart.who.int.pcmt030
/workspace/temp/ig-builds/smart.who.int.pcmt#0.1.0/fsh-generated/resources/StructureDefinition-MedicationCatalogItem011
/workspace/temp/ig-builds/smart.who.int.pcmt#0.1.0/fsh-generated/resources/StructureDefinition-Product000
/workspace/temp/ig-builds/smart.who.int.pcmt#0.1.0/fsh-generated/resources/StructureDefinition-ProductAuthorization000
/workspace/temp/ig-builds/smart.who.int.pcmt#0.1.0/fsh-generated/resources/StructureDefinition-ProductID010
/workspace/temp/ig-builds/smart.who.int.pcmt#0.1.0/fsh-generated/resources/ValueSet-AttributeType010
/workspace/temp/ig-builds/smart.who.int.pcmt#0.1.0/fsh-generated/resources/ValueSet-NameType010
/workspace/temp/ig-builds/smart.who.int.pcmt#0.1.0/fsh-generated/resources/ValueSet-ProductRelationship010
/workspace/temp/ig-builds/smart.who.int.pcmt#0.1.0/fsh-generated/resources/ValueSet-RegulationType030
/workspace/temp/ig-builds/smart.who.int.pcmt#0.1.0/fsh-generated/resources/ValueSet-Status010

n/a Show Validation Information

downloads​.html​#​/html​/body​/div​/div​/div​/div​/div​/ul​/li​/a at Line 295, column 8errorThe link 'definitions.xml.zip' for "XML" cannot be resolved HTML_LINK_CHECK_FAILED
downloads​.html​#​/html​/body​/div​/div​/div​/div​/div​/ul​/li​/a at Line 296, column 8errorThe link 'definitions.json.zip' for "JSON" cannot be resolved HTML_LINK_CHECK_FAILED
downloads​.html​#​/html​/body​/div​/div​/div​/div​/div​/ul​/li​/p​/a at Line 298, column 9errorThe link 'definitions.ttl.zip' for "TTL" cannot be resolved HTML_LINK_CHECK_FAILED
downloads​.html​#​/html​/body​/div​/div​/div​/div​/div​/ul​/li​/a at Line 312, column 8errorThe link 'examples.xml.zip' for "XML" cannot be resolved HTML_LINK_CHECK_FAILED
downloads​.html​#​/html​/body​/div​/div​/div​/div​/div​/ul​/li​/a at Line 313, column 8errorThe link 'examples.json.zip' for "JSON" cannot be resolved HTML_LINK_CHECK_FAILED
downloads​.html​#​/html​/body​/div​/div​/div​/div​/div​/ul​/li​/a at Line 314, column 8errorThe link 'examples.ttl.zip' for "TTL" cannot be resolved HTML_LINK_CHECK_FAILED

fsh-generated/resources/CodeSystem-AttributeType.json Show Validation Information (1)

PathSeverityMessage
CodeSysteminformationCodeSystems SHOULD have a stated value for the caseSensitive element so that users know the status and meaning of the code system clearly
CodeSystem (l1/c1206)warningPublished code systems SHOULD conform to the ShareableCodeSystem profile, which says that the element CodeSystem.experimental is mandatory, but it is not present CODESYSTEM_SHAREABLE_MISSING
CodeSystem (l1/c1206)warningPublished code systems SHOULD conform to the ShareableCodeSystem profile, which says that the element CodeSystem.caseSensitive is mandatory, but it is not present CODESYSTEM_SHAREABLE_MISSING

fsh-generated/resources/CodeSystem-ProductRelationship.json Show Validation Information (1)

PathSeverityMessage
CodeSysteminformationCodeSystems SHOULD have a stated value for the caseSensitive element so that users know the status and meaning of the code system clearly
CodeSystem (l1/c3537)warningPublished code systems SHOULD conform to the ShareableCodeSystem profile, which says that the element CodeSystem.experimental is mandatory, but it is not present CODESYSTEM_SHAREABLE_MISSING
CodeSystem (l1/c3537)warningPublished code systems SHOULD conform to the ShareableCodeSystem profile, which says that the element CodeSystem.caseSensitive is mandatory, but it is not present CODESYSTEM_SHAREABLE_MISSING

fsh-generated/resources/CodeSystem-RegulatationType.json Show Validation Information (1)

PathSeverityMessage
CodeSysteminformationCodeSystems SHOULD have a stated value for the caseSensitive element so that users know the status and meaning of the code system clearly
CodeSystem (l1/c1246)warningPublished code systems SHOULD conform to the ShareableCodeSystem profile, which says that the element CodeSystem.experimental is mandatory, but it is not present CODESYSTEM_SHAREABLE_MISSING
CodeSystem (l1/c1246)warningPublished code systems SHOULD conform to the ShareableCodeSystem profile, which says that the element CodeSystem.caseSensitive is mandatory, but it is not present CODESYSTEM_SHAREABLE_MISSING

fsh-generated/resources/CodeSystem-Status.json Show Validation Information (1)

PathSeverityMessage
CodeSysteminformationCodeSystems SHOULD have a stated value for the caseSensitive element so that users know the status and meaning of the code system clearly
CodeSystem (l1/c1170)warningPublished code systems SHOULD conform to the ShareableCodeSystem profile, which says that the element CodeSystem.experimental is mandatory, but it is not present CODESYSTEM_SHAREABLE_MISSING
CodeSystem (l1/c1170)warningPublished code systems SHOULD conform to the ShareableCodeSystem profile, which says that the element CodeSystem.caseSensitive is mandatory, but it is not present CODESYSTEM_SHAREABLE_MISSING

fsh-generated/resources/CodeSystem-pcmt-glossary-cs.json Show Validation Information (1)

PathSeverityMessage
CodeSysteminformationCodeSystems SHOULD have a stated value for the caseSensitive element so that users know the status and meaning of the code system clearly
CodeSystem (l1/c1074)warningPublished code systems SHOULD conform to the ShareableCodeSystem profile, which says that the element CodeSystem.experimental is mandatory, but it is not present CODESYSTEM_SHAREABLE_MISSING
CodeSystem (l1/c1074)warningPublished code systems SHOULD conform to the ShareableCodeSystem profile, which says that the element CodeSystem.caseSensitive is mandatory, but it is not present CODESYSTEM_SHAREABLE_MISSING

fsh-generated/resources/ImplementationGuide-smart.who.int.pcmt.json Show Validation Information (1)

PathSeverityMessage
ImplementationGuide​.meta​.profile[0] (l1​/c159)warningA definition could not be found for Canonical URL 'http://smart.who.int/smart-base/ImplementationGuide-SGImplementationGuide' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_RESOLVE
ImplementationGuide​.dependsOn[2] (l1​/c2318)warningThe ImplementationGuide uses package smart.who.int.base#0.1.0 released on 2024-09-20, but the most recent appropriate version is 0.2.0. This reference is getting old and the more recent version should be considered IG_DEPENDENCY_VERSION_WARNING_OLD
ImplementationGuide​.meta​.profile[0] (l1​/c22799)warningProfile reference 'http://smart.who.int/smart-base/ImplementationGuide-SGImplementationGuide' has not been checked because it could not be found, and the validator is set to not fetch unknown profiles VALIDATION_VAL_PROFILE_UNKNOWN_NOT_POLICY

fsh-generated/resources/StructureDefinition-MedicationCatalogItem.json Show Validation Information (1)

PathSeverityMessage
StructureDefinition​.snapshot​.element[4]​.binding​.extension[0] (l1​/c20134)informationThe extension http://hl7.org/fhir/StructureDefinition/elementdefinition-maxValueSet|5.2.0 is deprecated MSG_DEPENDS_ON_DEPRECATED
StructureDefinition​.where(url = 'http:​/​/smart​.who​.int​/pcmt​/StructureDefinition​/MedicationCatalogItem')warningThe Implementation Guide contains no examples for this profile

fsh-generated/resources/StructureDefinition-Product.json Show Validation Information (1)


fsh-generated/resources/StructureDefinition-ProductAuthorization.json Show Validation Information (1)


fsh-generated/resources/StructureDefinition-ProductID.json Show Validation Information (1)

PathSeverityMessage
StructureDefinition​.where(url = 'http:​/​/smart​.who​.int​/pcmt​/StructureDefinition​/ProductID')warningThe Implementation Guide contains no examples for this extension

fsh-generated/resources/ValueSet-AttributeType.json Show Validation Information (1)

PathSeverityMessage
ValueSet (l1/c845)warningPublished value sets SHOULD conform to the ShareableValueSet profile, which says that the element ValueSet.experimental is mandatory, but it is not present

fsh-generated/resources/ValueSet-NameType.json Show Validation Information (1)

PathSeverityMessage
ValueSet (l1/c809)warningPublished value sets SHOULD conform to the ShareableValueSet profile, which says that the element ValueSet.experimental is mandatory, but it is not present

fsh-generated/resources/ValueSet-ProductRelationship.json Show Validation Information (1)

PathSeverityMessage
ValueSet (l1/c909)warningPublished value sets SHOULD conform to the ShareableValueSet profile, which says that the element ValueSet.experimental is mandatory, but it is not present

fsh-generated/resources/ValueSet-RegulationType.json Show Validation Information (1)

PathSeverityMessage
ValueSet​.compose​.include[0]​.system (l1​/c834)warningNo definition could be found for URL value 'http://smart.who.int/pcmt/CodeSystem/RegulationType' Type_Specific_Checks_DT_URL_Resolve
ValueSet (l1/c838)warningPublished value sets SHOULD conform to the ShareableValueSet profile, which says that the element ValueSet.experimental is mandatory, but it is not present
ValueSet.where(id = 'RegulationType')warningError from https://tx.fhir.org/r4: Unable to provide support for code system http://smart.who.int/pcmt/CodeSystem/RegulationType (from server, see log)

fsh-generated/resources/ValueSet-Status.json Show Validation Information (1)

PathSeverityMessage
ValueSet (l1/c775)warningPublished value sets SHOULD conform to the ShareableValueSet profile, which says that the element ValueSet.experimental is mandatory, but it is not present

Suppressed Messages (Warnings, hints, broken links)

No suppressed messsages

Errors sorted by type


CODESYSTEM_SHAREABLE_MISSING

fsh-generated/resources/CodeSystem-AttributeType.jsonPublished code systems SHOULD conform to the ShareableCodeSystem profile, which says that the element CodeSystem.experimental is mandatory, but it is not present
fsh-generated/resources/CodeSystem-AttributeType.jsonPublished code systems SHOULD conform to the ShareableCodeSystem profile, which says that the element CodeSystem.caseSensitive is mandatory, but it is not present
fsh-generated/resources/CodeSystem-ProductRelationship.jsonPublished code systems SHOULD conform to the ShareableCodeSystem profile, which says that the element CodeSystem.experimental is mandatory, but it is not present
fsh-generated/resources/CodeSystem-ProductRelationship.jsonPublished code systems SHOULD conform to the ShareableCodeSystem profile, which says that the element CodeSystem.caseSensitive is mandatory, but it is not present
fsh-generated/resources/CodeSystem-RegulatationType.jsonPublished code systems SHOULD conform to the ShareableCodeSystem profile, which says that the element CodeSystem.experimental is mandatory, but it is not present
fsh-generated/resources/CodeSystem-RegulatationType.jsonPublished code systems SHOULD conform to the ShareableCodeSystem profile, which says that the element CodeSystem.caseSensitive is mandatory, but it is not present
fsh-generated/resources/CodeSystem-Status.jsonPublished code systems SHOULD conform to the ShareableCodeSystem profile, which says that the element CodeSystem.experimental is mandatory, but it is not present
fsh-generated/resources/CodeSystem-Status.jsonPublished code systems SHOULD conform to the ShareableCodeSystem profile, which says that the element CodeSystem.caseSensitive is mandatory, but it is not present
fsh-generated/resources/CodeSystem-pcmt-glossary-cs.jsonPublished code systems SHOULD conform to the ShareableCodeSystem profile, which says that the element CodeSystem.experimental is mandatory, but it is not present
fsh-generated/resources/CodeSystem-pcmt-glossary-cs.jsonPublished code systems SHOULD conform to the ShareableCodeSystem profile, which says that the element CodeSystem.caseSensitive is mandatory, but it is not present

IG_DEPENDENCY_VERSION_WARNING_OLD

fsh-generated/resources/ImplementationGuide-smart.who.int.pcmt.jsonThe ImplementationGuide uses package smart.who.int.base#0.1.0 released on 2024-09-20, but the most recent appropriate version is 0.2.0. This reference is getting old and the more recent version should be considered

MSG_DEPENDS_ON_DEPRECATED

fsh-generated/resources/StructureDefinition-MedicationCatalogItem.jsonThe extension http://hl7.org/fhir/StructureDefinition/elementdefinition-maxValueSet|5.2.0 is deprecated

TYPE_SPECIFIC_CHECKS_DT_CANONICAL_RESOLVE

fsh-generated/resources/ImplementationGuide-smart.who.int.pcmt.jsonA definition could not be found for Canonical URL 'http://smart.who.int/smart-base/ImplementationGuide-SGImplementationGuide'

Type_Specific_Checks_DT_URL_Resolve

fsh-generated/resources/ValueSet-RegulationType.jsonNo definition could be found for URL value 'http://smart.who.int/pcmt/CodeSystem/RegulationType'

VALIDATION_VAL_PROFILE_UNKNOWN_NOT_POLICY

fsh-generated/resources/ImplementationGuide-smart.who.int.pcmt.jsonProfile reference 'http://smart.who.int/smart-base/ImplementationGuide-SGImplementationGuide' has not been checked because it could not be found, and the validator is set to not fetch unknown profiles